Skip to content
GitLab
Projects Groups Snippets
  • /
  • Help
    • Help
    • Support
    • Community forum
    • Submit feedback
    • Contribute to GitLab
  • Sign in
  • bob.db.verafinger bob.db.verafinger
  • Project information
    • Project information
    • Activity
    • Labels
    • Members
  • Repository
    • Repository
    • Files
    • Commits
    • Branches
    • Tags
    • Contributors
    • Graph
    • Compare
  • Issues 1
    • Issues 1
    • List
    • Boards
    • Service Desk
    • Milestones
  • Merge requests 0
    • Merge requests 0
  • CI/CD
    • CI/CD
    • Pipelines
    • Jobs
    • Schedules
  • Deployments
    • Deployments
    • Environments
    • Releases
  • Monitor
    • Monitor
    • Incidents
  • Analytics
    • Analytics
    • Value stream
    • CI/CD
    • Repository
  • Activity
  • Graph
  • Create a new issue
  • Jobs
  • Commits
  • Issue Boards
Collapse sidebar
  • bobbob
  • bob.db.verafingerbob.db.verafinger
  • Issues
  • #1
Closed
Open
Issue created Nov 21, 2017 by Vedrana KRIVOKUCA@vkrivokucaMaintainer

Full protocol includes comparison of template to itself

The "Full" protocol contains match scores of 0.5, which comes from comparing each template to itself. For my work, I have removed these scores manually, but I think it would be better to modify the protocol so that it only contains match scores for DIFFERENT samples (i.e., not for a sample compared with itself). Below is an example of the EER results obtained for our 3 fingervein extractors (WLD, RLT and MC) with the Full protocol as it is VERSUS when the scores of 0.5 are removed:

WLD: 5.795% (current Full protocol) versus 9.545% (scores of 0.5 removed)

RLT: 14.545% (current Full protocol) versus 24.318% (scores of 0.5 removed)

MC: 2.477% (current Full protocol) versus 4.318% (scores of 0.5 removed)

Edited Nov 21, 2017 by Vedrana KRIVOKUCA
Assignee
Assign to
Time tracking